HOME The Profile The Products Enquire Us Certifications/Awards News/Downloads Contact Us
Analog Multi Meter
Digital Multi Meter
Bench Type Multi Meter
Clamp Meter
Insulation Resistance Tester
Earth Tester
Laser Power Meter
Lux Meter
Thermo Meter
Tachometer
Phase Detector
Logic Tester
Cord Tester
Calibrator
Optional Accessory
PC Link System
Analog Oscilloscopes
Digital Oscilloscope
Probe for oscilloscopes
Signal / Function Generators
Arbitrary Function Generators
Arbitrary Waveform Generators
Spectrum Analyzer
Real Time Spectrum Analyzer
Logic Analyzers
Power Supplies
Component Testing Instruments
Other Instruments

 
GOS-6030

Features:
  • 30MHZ Bandwidth
  • Vertical : 1mV/div ~ 20V/div
  • ALT MAG Function (x 5, x 10, x 20)
  • Vertical Mode Triggering
  • TV Synchronization
Analog Oscilloscopes
GOS-6030

Specifications
CRT
Type 6-inch rectangular type with internal graticule; 0%, 10%, 90%, 100% markers. 8x10 div(1div=1cm)
Accelerating Potential Approx.2kV
Trace Rotation Provided
Z-axis input Sensitivity : at least 5V ; Polarity : positive going input decrease intensity
Usable frequency range : DC to 2MHZ ; Max. input voltage : 30V (DC + AC peak) at 1KHZ or less
Input Impedance : Approx.47k£[
VERTICAL SYSTEM
Sensitivity and Accuracy 1mV ~ 2mV/div ¡Ó5%, 5mV ~ 20V/div ¡Ó3%, 14 calibrated steps in 1-2-5 sequence
Vernier Vertical Sensitivity Continuously variable to 1/2.5 or less of panel indicate value
Bandwidth (-3dB) and Rise Time
  Bandwidth (-3dB) Rise Time
5mV ~ 20V/div
DC ~ 30MHZ
Approx. 11.7nS
1mV ~ 2mV/div DC ~ 7MHZ Approx. 50nS
Maximum Input Voltage 400V (DC + AC peak) at 1KHZ or less
Input Coupling
AC, DC, GND
Input Impedance 1M£[ ¡Ó2%//approx. 25pF
Vertical Modes CH1, CH2, DUAL (CHOP, ALT), ADD, CH2 INV
Chop Frequency Approx. 250KHZ
Dynamic Range 8 div at 20MHZ, 6div at 30MHZ
HORIZONTAL SYSTEM
Sweep Time
0.2£gs/div ~ 0.5s/div, 20 steps selectable in 1-2-5 sequence, continuous variable control between
steps at least 1 : 2.5
Accuracy ¡Ó3%, ¡Ó5% at x5 / x10MAG, ¡Ó8% at x 20MAG
Sweep Magnification x5, x10, x20 MAG
Maximum Sweep Time (at MAG) 50ns/div (10ns/div~40ns/div are uncalibrated)
ALT-MAG Function Available
TRIGGER
Trigger Mode AUTO, NORM,TV
Trigger Source VERT-MODE, CH1, CH2, LINE, EXT
Trigger Coupling AC, HFR, LFR, TV-V(-), TV-H(-)
Trigger Slope ¡§+¡¨or¡§ - ¡¨polarity
Trigger Sensitivity
  20HZ~2MHZ 2MHZ~20MHZ 20MHZ~30MHZ
CH1, CH2 0.5div 1.5div 2.0div
Vert-Mode 2.0div 3.0div 3.5div
EXT 200mV 800mV 1V

TV sync pulse more than 1 div (CH1, CH2, VERT-MODE) or 200mV (EXT)
External Trigger Input Input impedance: Approx.1M£[//25pF(AC coupling);Max. input voltage: 400V(DC+AC peak)at 1KHZ
Hold-off Time Variable
X-Y OPERATION
Input X-axis : CH1 ; Y-axis : CH2
Sensitivity 1mV/div ~ 20V/div
Bandwidth X-axis : DC ~ 500KHZ (-3dB)
Phase Difference 3¢Xor less from DC to 50KHZ
OUTPUT SIGNAL
CH1 Signal Output Voltage : approx. 20mV/div (with 50£[ terminated)
Bandwidth : 50HZ to at least 5MHZ
Calibrator Output Voltage : 0.5V¡Ó3%
Frequency : approx. 1KHZ, square wave
CRT READOUT
Panel Setting Display
CH1/CH2 sensitivity, sweep time, trigger condition
Panel Setting Save & Recall 10 sets
POWER SOURCE
  AC 100V/120V/230V¡Ó10%, 50/60HZ
ACCESSORIES
  Instruction manual x 1
Power cord x 1
GLF-190C Probes (10:1/1:1) x 2
DIMENSIONS & WEIGHT
  275(W) x 130(H) x 370(D) mm
Approx. 7.2kg

About Us - Products - Enquiry - News / Downloads - Contact Us