HOME The Profile The Products Enquire Us Certifications/Awards News/Downloads Contact Us
Alt
Analog Multi Meter
Digital Multi Meter
Bench Type Multi Meter
Clamp Meter
Insulation Resistance Tester
Earth Tester
Laser Power Meter
Lux Meter
Thermo Meter
Tachometer
Phase DetectorAlt
Logic Tester
Cord Tester
Calibrator
Optional Accessory
PC Link System
Analog Oscilloscopes
Digital Oscilloscope
Probe for oscilloscopes
Signal / Function Generators
Arbitrary Function Generators
Arbitrary Waveform Generators
Spectrum Analyzer
Real Time Spectrum Analyzer
Logic Analyzers
Electric Safety TesterAlt
AC Power MeterAlt
Power Supplies
Digital Frequency CounterAlt
Component Testing Instruments
Other Instruments
Alt

 
RSA3303A • RSA3308

Features:
  • Trigger
    • Tektronix' Exclusive Frequency Mask Trigger Makes Event-based Capture of Transient RF Signals Easy By Triggering on Any Change in the Frequency Domain
  • Capture
    • All Input Signals up to 15 MHZ*1 Spans Are Seamlessly Captured Into Memory
    • Long Record Length Enables Complete Analysis Over Time Without Making Multiple Acquisitions
    • Interfaces With TekConnect® Probes for RF and Baseband Probing
  • Analyze
    • Gain a Unique Understanding of Time-varying Transient RF Signals
    • Spectrogram Provides a Revealing Picture of RF Signal Frequency and Amplitude Behavior Over Time – Not possible With a Swept Spectrum Analyzer
    • Multi-domain Analysis Enables Fast, Complete Signal Analysis in Frequency, Time, Code and Modulation Domains Without Making Multiple Measurements
    • Simple Capture and Analysis on RFID Interrogator and Response Signals
    • Comprehensive Pulse Measurement Suite
    • General Purpose Digital Modulation Analysis
    • Spectrum Analyzer View for Traditional Wide Band Signal Analysis
    • 3G Measurement Versatility with W-CDMA, cdma2000, 1X EVDO, HSDPA, TD-SCDMA RF and Modulation Analysis (WCA200A Only)
    • Signal Source Analysis Simplifies Phase Noise, Jitter and Frequency Settling Measurements
Real Time Spectrum Analyzer
RSA3300A
Optional Accessories

Applications

  • System Integration of 3G, and Other RF Systems
  • Radar and Pulsed RF Signal Characterization
  • RFID System Development and Troubleshooting
  • General Purpose Phase Noise and Jitter Signal Analysis
  • Characterization of Interfering or Unknown Signals in Spectrum Monitoring and Surveillance
  • Troubleshooting RF Components, Modules, or Systems
  • Getting Answers to Elusive EMI Diagnostic Problems
Characteristics
Trigger-related

Trigger Mode - Free run (triggered by acquisition), Triggered (Triggered by event), Single, or Continuous

Trigger Event Source - Power (span BW), Frequency Mask (Opt. 02), External

Pre-/Post-Trigger Setting - Trigger position settable within 0 to 100% of total acquisition length

Trigger Marker Position Timing Uncertainty (Power and External Trigger) - ±2 sample points

FREQUENCY MASK TRIGGER (Opt. 02)

Mask Resolution - 1 bin

Level Range - 0 dBfs*2 to -60 dBfs at 10 dB/div vertical scale

Bandwidth -

Up to 15 MHZ: Start frequency =20 MHZ

Up to 20 MHZ: Start frequency <20 MHZ

Mask Shape - User-defined

Minimum Horizontal Mask Setting Resolution - <0.2% of span

Uncertainty - ±2 frames

POWER TRIGGER

Level Range - 0 dBfs to -40 dBfs

LEVEL TRIGGER

Level Range - 1 to 100%

EXTERNAL TRIGGER

Threshold Voltage - -1.5 V to +1.5 V

Threshold Voltage Setting Resolution - 0.1 V

Input Impedance - >2 kO

TRIGGER OUTPUT

Voltage (Output Current <1 mA) - HIGH: >2.0 V; LOW: <0.4 V

*2 dBfs: dB relative to full scale

Capture-related

Real-Time Capture Bandwidth - 15 MHZ RF; 20 MHZ baseband; 20 MHZ using Opt. 03 IQ inputs

A/D Converter - 51.2 MS/s, 14 bits

Minimum Acquisition Length in RTSA/Time/Demod Modes - 1024 samples

Maximum Acquisition Length in RTSA/Time/Demod Modes - 16,384,000 samples; 65,636,000 samples, Opt. 02

Acquisition Length Setting Resolution in RTSA/Time/Demod Modes -  

Acquisition Memory Size - 16.4 MSamples; 65.6 MSamples, Opt. 02

Block Size (number of frames) - 1 to 16,000; 1 to 64,000, Opt. 02

Memory Depth (time) and Maximum Time Resolution

Span

Sample Rate

(For I and Q)

Record Length

Record Length (Opt. 02)

Spectrum Frame (Time)

Max Time (Resolution)

20 MHZ (Baseband)

25.6 MS/s

0.64 s

2.56 s

40 µs

40 ns

15 MHZ

25.6 MS/s

0.64 s

2.56 s

40 µs

40 ns

10 MHZ

12.8 MS/s

1.28 s

5.12 s

80 µs

80 ns

5 MHZ

6.4 MS/s

2.56 s

10.24 s

160 µs

160 ns

2 MHZ

3.2 MS/s

6.4 s

20.48 s

320 µs

320 ns

1 MHZ

1.6 MS/s

12.8 s

40.96 s

640 µs

640 ns

500 KHZ

800 KS/s

25.6 s

81.92 s

1.28 ms

1.25 µs

200 KHZ

320 KS/s

64 s

204.8 s

3.2 ms

3.2 µs

100 KHZ

160 KS/s

128 s

409.6 s

6.4 ms

6.4 µs

50 KHZ

80 KS/s

256 s

819.2 s

12.8 ms

12.8 µs

20 KHZ

32 KS/s

640 s

2048 s

32 ms

32 µs

10 KHZ

16 KS/s

1280 s

4096 s

64 ms

64 µs

5 KHZ

8 KS/s

2560 s

8192 s

128 ms

128 µs

2 KHZ

3.2 KS/s

6400 s

20480 s

320 ms

320 µs

1 KHZ

1.6 KS/s

12800 s

40960 s

640 ms

640 µs

500 HZ

800 KS/s

25600 s

81920 s

1.28 s

1.28 ms

200 HZ

320 S/s

64000 s

204800 s

3.2 s

3.2 ms

100 HZ

160 S/s

128000 s

409600 s

6.4 s

6.4 ms

Analysis-related

Measurement Functions by Mode

Mode

Measurements

SA

Channel Power, Adjacent Channel Power Ratio,occupied Bandwidth, Emission Bandwidth, Carrier-to-Noise Ratio, Carrier Frequency

RTSA

Channel Power, Adjacent Channel Power Ratio,occupied Bandwidth, Emission Bandwidth, Carrier-to-Noise Ratio, Carrier Frequency

Time

IQ vs. Time, Power vs. Time, Frequency vs. Time, CCDF, Crest Factor Pulse Measurements: Pulse Width, Pulse Peak Power, On/Off Ratio, Pulse Ripple, Pulse Repetition Interval, Duty Cycle, Pulse-Pulse Phase, Channel Power, OBW, EBW, Frequency Deviation (Min pulse length, 20 samples; Max pulse length, 360,000 samples)

Analog Demod

IQ vs. Time, AM Depth, FM Deviation, PM Deviation, Pulse Spectrum

Views by Mode

Mode

Views

SA

Spectrum

SA/Spectrogram

Spectrum, Spectrogram

RTSA

Spectrum, Spectrogram

Time

Overview: Power vs. Time, Spectrogram

Sub-view: Spectrum

Main view: Measurement Result

Analog Demod

Overview: Power vs. Time, Spectrogram

Sub-view: Spectrum

Main view: Measurement Result


Screen layout, to identify analysis view locations as described in the above chart

MEASUREMENT SPEED

Screen Update Rate - 2 MHZ Span, Auto RBW: 19.4/s

Remote Measurement Rate and GPIB Transfer Rate (2 MHZ span, auto RBW, spectrum data) - 1.87 waveforms/s, or 6,000 samples/s

RF Center Frequency Switching Time -  

<10 ms for 10 MHZ frequency change

500 ms for 3 GHZ frequency change

TRACES, DISPLAYS, DETECTORS

Traces - Two traces, Spectrum Analyzer mode

Displays - Up to three time-correlated, user-selected displays

Detector - RMS

Trace Types - Normal (RMS), Average, Max Hold, Min Hold

Display Detection - Max, Min, Max/Min

MODULATION ANALYSIS

Analog

AM

Minimum Input Level - -40 dBfs, typical

PM

Minimum Input Level - -40 dBfs, typical

PM Scale, Max, Min - ±180°

FM

Minimum Input Level - -40 dBfs, typical

Range - ±Span/2 from center frequency

DEMODULATION ACCURACY

Analog

AM (-10 dBfs signal, input at CF, 10 to 60% modulation depth) - ±2%

PM (-10 dBfs signal, input at CF) - ±3°

FM (-10 dBfs signal, input at CF) - ±1% of span

RF Performance

FREQUENCY

Frequency Range -  

RSA3308A/WCA280A: DC to 8 GHZ

RSA3303A/WCA230A: DC to 3 GHZ

Center Frequency Setting Resolution - 0.1 HZ

Frequency Marker Readout Accuracy, Baseband - ±(RE*3 × MF*4 + 0.001 × Span + 0.2) HZ

Frequency Marker Readout Accuracy, RF - ±(RE × MF + 0.001 × Span + 2) HZ

Span Accuracy - ±1 bin

RBW Filter Bandwidth Accuracy - 0.1%

Reference Frequency -  

Aging per day - 1 × 10-9 (after 30 days of operation).

Aging per year - 1 × 10-7 (after 30 days of operation).

Temperature Drift - 1 × 10-7 (10 to 40 °C).

Total Frequency Error - 2 × 10-7 (within one year of calibration).

Reference Output Level - >0 dBm.

External Reference Input - 10 MHZ, -10 dBm to + 6 dBm.

Frequency Span -  

Range, Spectrum Analyzer Mode -  

50 HZ to 3 GHZ (Start Frequency =40 MHZ)

0 HZ to 40 MHZ (Stop Frequency <40 MHZ)

Range, Real-Time Spectrum Analyzer Mode -  

100 HZ to 15 MHZ (RF)

0 HZ to 20 MHZ (Baseband)

Resolution Bandwidth Range - 2 KHZ to 2 MHZ, automatically selected or user-defined

Accuracy - Within 6.0% ±0.1%

Shape Characteristic - Gaussian with <5:1 shape factor (3:60 dB)

Rectangular, Nyquist, Root Nyquist shapes may also be selected.

*3 RE: Reference Frequency Error

*4 MF: Marker Frequency (HZ)

Minimum Settable RBW (Extended Resolution ON)

Frequency

RBW

Span >2 GHZ

100 KHZ

1 GHZ <Span =2 GHZ

50 KHZ

500 MHZ <Span =1 GHZ

20 KHZ

20 MHZ <Span =500 MHZ

10 KHZ

500 KHZ <Span =20 MHZ

1 KHZ

200 KHZ <Span =500 KHZ

500 HZ

100 KHZ <Span =200 KHZ

200 HZ

50 KHZ <Span =100 KHZ

100 HZ

20 KHZ <Span =50 KHZ

50 HZ

10 KHZ <Span =20 KHZ

20 HZ

5 KHZ <Span =10 KHZ

10 HZ

2 KHZ <Span =5 KHZ

5 HZ

1 KHZ <Span =2 KHZ

2 HZ

100 HZ <Span =1 KHZ

1 HZ

Noise Bandwidth Range, RTSA Mode - 313.18 MHZ to 400.87 KHZ

FFT Performance -  

Number of samples per frame - 64 to 8192 (65,536 samples per frame, extended resolution).

Window types - Rectangular, Parzen, Welch, Sine-Lobe, Hanning, Sine-cubed, Sine-to-the-4th, Hamming, Blackman, Rosenfield, Blackman-Harris 3A, Blackman-Harris 3B, Blackman-Harris 4A, Blackman-Harris 4B, FlatTop.

STABILITY

Noise Sidebands, dBc/HZ

Offset

At 1 GHZ CF

At 2 GHZ CF

At 6 GHZ CF

   

Spec

Typical

Spec

Typical

Spec

Typical

1 KHZ

-100

-107

-96

-99

-87

-90

10 KHZ

-105

-112

-104

-107

-104

-107

20 KHZ

-105

-112

-105

-108

-105

-108

30 KHZ

-105

-112

-105

-108

-105

-108

100 KHZ

-112

-115

-112

-115

-112

-115

1 MHZ

-132

-135

-132

-135

-128

-131

5 MHZ

-135

-140

-135

-138

-130

-133

7 MHZ

-135

-140

-135

-138

-130

-133

Residual FM - 2 HZ, pk-pk, typical.

AMPLITUDE

Measurement Range - Displayed average noise level to MAX safe input.

Input Attenuator Range -  

RF/Baseband Input - 0 dB to 50 dB, 5 dB step.

IQ Input (Opt. 03) - 0 dB to 30 dB, 10 dB step.

Input Attenuator Setting Uncertainty - ±0.5 dB (at 50 MHZ).

Maximum Safe Input Level -  

Average Continuous (RF band, RF ATT =10 dB) - +30 dB.

MAX DC Voltage -  

±0.2 V, RF

±5 V, Baseband

±5 V, IQ input w/ Opt. 03

Log Display Range - 10 µdB/div to 10 dB/div

Linear Display Scale - 10 divisions

Linear Display Units - dBm, dBµV, V, Watts, HZ for FM Demod, Degrees for PM Demod

Marker Readout Resolution, Log - 0.01 dB

Marker Readout Resolution, Linear - 0.001 µV

Frequency Response, 20 °C to 30 °C, RF ATT =10 dB

Frequency

Spec

Typical

100 KHZ - 40 MHZ

±0.5 dB

±0.3 dB

40 MHZ - 3.0 GHZ

±1.2 dB

±0.5 dB

3.0 GHZ - 6.5 GHZ*5

±1.7 dB

±1.0 dB

5 GHZ - 8 GHZ*5

±1.7 dB

± 1.0 dB

Absolute Amplitude Accuracy at Calibration Point (Baseband at 25 MHZ, -10 dBm signal, 0 dB ATT, 20 °C to 30 °C) - ±0.3 dB

Absolute Amplitude Accuracy at Calibration Point (RF at 100 MHZ, -20 dBm signal, 0 dB ATT, 20 °C to 30 °C) - ±0.5 dB

Reference Level Setting Range -  

1 dB step, RF, -50 dBm to +30 dBm

5 dB step, Baseband, -30 dBm to +20 dBm

5 dB step, IQ, -10 dBm to +20 dBm

Reference Level Accuracy (-10 dBm to -50 dBm at 100 MHZ, 10 dB ATT, 20 °C to 30 °C) - ±0.2 dB

Level Linearity in Display Range - ±0.2 dB, spec; ±0.12 dB, typical

SPURIOUS RESPONSE

1 dB Compression (RF ATT = 0 dB, 2 GHZ CF) - +2 dBm

3rd Order Inter-modulation Distortion (Ref Level = +5 dBm, RF ATT: adjusted for optimum, total signal power = -7 dBm, CF = 2 GHZ) - -74 dBc

2nd Harmonic Distortion (-30 dBm tone at input mixer, 10 MHZ to 1750 MHZ) - -56 dBc, typical.

Displayed Average Noise Level, Specified, dBm/HZ

Frequency

Spec

10 MHZ

-151

2 GHZ

-150

3 GHZ

-150

7 GHZ*5

-142

Displayed Average Noise Level, Typical, dBm/HZ

Frequency

Typical

1 KHZ -10 KHZ

-144

10 KHZ -10 MHZ

-151

10 MHZ -100 MHZ

-151

100 MHZ -1 GHZ

-150

1 GHZ - 2 GHZ

--150

2 GHZ -3 GHZ

-150

3 GHZ - 5 GHZ*5

-142

5 GHZ - 8 GHZ*5

-142

Residual Response

Frequency

Spec

1 to 40 MHZ (Span =20 MHZ, Ref Lvl =-30 dBm, RBW -100 KHZ)

-93 dBm

0.5 to 3.5 GHZ (Span =3 GHZ, Ref Lvl =-30 dBm, RBW =100 KHZ)*5

-90 dBm

3.5 to 6.5 GHZ (Span =3 GHZ, Ref Lvl =-30 dBm, RBW =100 KHZ)*5

-85 dBm

3.5 to 8 GHZ (Span =3 GHZ, Ref Lvl =-30 dBm, RBW =100 KHZ)*5

-85 dBm

Spurious Response with Signal

Frequency

Spec

0 MHZ (Span =10 MHZ, Ref Lvl =0 dBm, RBW -50 KHZ, Signal Frequency =25 MHZ, Signal Level =-5 dBm)

-73 dBc

2 GHZ (Span =10 MHZ, Ref Lvl =0 dBm, RBW -50 KHZ, Signal Frequency =2 GHZ, Signal Level =-5 dBm)

-73 dBc

5 GHZ (Span =10 MHZ, Ref Lvl =0 dBm, RBW -50 KHZ, Signal Frequency =5 GHZ, Signal Level =-5 dBm)*5

-70 dBc

7 GHZ (Span =10 MHZ, Ref Lvl =0 dBm, RBW -50 KHZ, Signal Frequency =7 GHZ, Signal Level =-5 dBm)*5

-70 dBc

*5 Frequency >3 MHZ available on RSA3308A, WCA280A only

INPUTS AND OUTPUTS

Front Panel

Input Connectors - N type, RF/Baseband; BNC type, IQ, Opt. 03

Input Impedance - 50 O

VSWR, RF ATT >10 dB

Frequency

Spec

Typical

300 KHZ -10 MHZ

-

<1.4:1

10 MHZ - 3 GHZ

-

<1.3:1

2.5 GHZ

<1.4:1

-

7.5 GHZ

<1.8:1

-

Preamp Power Connector - LEMO 6 pin connector - Pin 1: NC; Pin 2: ID1; Pin 3: ID2; Pin 4: -12 V; Pin 5: GND; Pin 6: +12 V.

External Preamp (Opt. 1A) - 100MHZ - 3GHZ, 20 dB gain, 6.5 dB Noise Figure at 2 GHZ (Typical)

Rear Panel

10 MHZ REF OUT - 50 O, BNC, >-3 dBm

10 MHZ REF IN - 50 O, BNC, -10 dBm to +6 dBm

EXT TRIG IN - Ext Trig, BNC, High: 1.6 to 5.0 V, Low: 0 to 0.5 V

GPIB Interface - IEEE 488.2

TRIGGER OUT - 50 O, BNC, High: >2.0 V, Low: <0.4 V (output current 1 mA)

Side Panel

LAN Interface - Ethernet 10/100Base-T (Standard)

Serial Interface - USB 1.1, 2 ports

VGA Output - VGA compatible, 15 DSUB

General Characteristics

Temperature -

Operating: +10 °C to +40 °C.

Storage: -20 °C to +60 °C.

Warm-up Time - 20 min.

Altitude -  

Operating: up to 3000 m (10,000 ft.).

Non-operating: up to 12,000 m (40,000 ft.).

Safety and EMI Compatibility -

UL 61010-1; CSA C22.2 No. 61010-1-04; IEC61010, Second Edition (Self Declaration).

Low Voltage Directive 73/23/EEC, amended by 93/68/EEC; EN61010-1: 2001 Safety Requirements for Electrical Equipment for Measurement Control and Laboratory Use.

EC Council EMC Directive 89/336/EEC, amended by 93/68/EEC.

EN61326-1: 1997 Product Family Standard for Electrical Equipment for Measurement, Control, and Laboratory Use-EMC Requirements.

Electromagnetic Compatibility Framework:1992 AS/NZS 2064.1/2(Industrial, Scientific, and Medical Equipment).

Power Requirements - 100 VAC to 240 VAC, 47 HZ to 63 HZ.

Power Consumption - 400 VA max.

Data Storage - Internal HDD (40 GB), USB port, FDD.

Weight, without options - 19 kg, 42 lbs.

Dimensions -  

Without bumpers and feet: 215 mm (H) × 425 mm (D) × 425 mm (W).

With bumpers and feet: 238 mm (H) × 470 mm (D) × 445 mm (W).

Calibration Interval - 1 year.

Warranty - 1 year.

GPIB - SCPI-compatible.

About Us - Products - Enquiry - News / Downloads - Contact Us

© Copyright SPI Engineers Pvt. Ltd.  -  All rights reserved   -  Privacy policy/Disclaimer   -  Terms of use