Characteristics
Trigger-related
Trigger Mode - Free run (triggered by acquisition),
Triggered (Triggered by event), Single, or Continuous
Trigger Event Source - Power (span BW), Frequency
Mask (Opt. 02), External
Pre-/Post-Trigger Setting - Trigger position
settable within 0 to 100% of total acquisition length
Trigger Marker Position Timing Uncertainty (Power
and External Trigger) - ±2 sample points
FREQUENCY MASK TRIGGER (Opt. 02)
Mask Resolution - 1 bin
Level Range - 0 dBfs*2 to
-60 dBfs at 10 dB/div vertical scale
Bandwidth -
Up to 15 MHZ: Start frequency =20 MHZ
Up to 20 MHZ: Start frequency <20 MHZ
Mask Shape - User-defined
Minimum Horizontal Mask Setting Resolution - <0.2%
of span
Uncertainty - ±2 frames
POWER TRIGGER
Level Range - 0 dBfs to -40 dBfs
LEVEL TRIGGER
Level Range - 1 to 100%
EXTERNAL TRIGGER
Threshold Voltage - -1.5 V to +1.5 V
Threshold Voltage Setting Resolution - 0.1 V
Input Impedance - >2 kO
TRIGGER OUTPUT
Voltage (Output Current <1 mA) - HIGH:
>2.0 V; LOW: <0.4 V
*2 dBfs: dB relative to full scale
Capture-related
Real-Time Capture Bandwidth - 15 MHZ
RF; 20 MHZ baseband; 20 MHZ using Opt. 03
IQ inputs
A/D Converter - 51.2 MS/s, 14 bits
Minimum Acquisition Length in RTSA/Time/Demod
Modes - 1024 samples
Maximum Acquisition Length in RTSA/Time/Demod
Modes - 16,384,000 samples; 65,636,000 samples,
Opt. 02
Acquisition Length Setting Resolution in RTSA/Time/Demod
Modes -
Acquisition Memory Size - 16.4 MSamples; 65.6
MSamples, Opt. 02
Block Size (number of frames) - 1 to 16,000;
1 to 64,000, Opt. 02
Memory Depth (time) and Maximum Time Resolution
|
Span |
Sample Rate
(For I and Q) |
Record Length |
Record Length (Opt. 02) |
Spectrum Frame (Time) |
Max Time (Resolution) |
|
20 MHZ (Baseband) |
25.6 MS/s |
0.64 s |
2.56 s |
40 µs |
40 ns |
|
15 MHZ |
25.6 MS/s |
0.64 s |
2.56 s |
40 µs |
40 ns |
|
10 MHZ |
12.8 MS/s |
1.28 s |
5.12 s |
80 µs |
80 ns |
|
5 MHZ |
6.4 MS/s |
2.56 s |
10.24 s |
160 µs |
160 ns |
|
2 MHZ |
3.2 MS/s |
6.4 s |
20.48 s |
320 µs |
320 ns |
|
1 MHZ |
1.6 MS/s |
12.8 s |
40.96 s |
640 µs |
640 ns |
|
500 KHZ |
800 KS/s |
25.6 s |
81.92 s |
1.28 ms |
1.25 µs |
|
200 KHZ |
320 KS/s |
64 s |
204.8 s |
3.2 ms |
3.2 µs |
|
100 KHZ |
160 KS/s |
128 s |
409.6 s |
6.4 ms |
6.4 µs |
|
50 KHZ |
80 KS/s |
256 s |
819.2 s |
12.8 ms |
12.8 µs |
|
20 KHZ |
32 KS/s |
640 s |
2048 s |
32 ms |
32 µs |
|
10 KHZ |
16 KS/s |
1280 s |
4096 s |
64 ms |
64 µs |
|
5 KHZ |
8 KS/s |
2560 s |
8192 s |
128 ms |
128 µs |
|
2 KHZ |
3.2 KS/s |
6400 s |
20480 s |
320 ms |
320 µs |
|
1 KHZ |
1.6 KS/s |
12800 s |
40960 s |
640 ms |
640 µs |
|
500 HZ |
800 KS/s |
25600 s |
81920 s |
1.28 s |
1.28 ms |
|
200 HZ |
320 S/s |
64000 s |
204800 s |
3.2 s |
3.2 ms |
|
100 HZ |
160 S/s |
128000 s |
409600 s |
6.4 s |
6.4 ms |
Analysis-related
Measurement Functions by Mode
| Mode |
Measurements |
| SA |
Channel Power, Adjacent
Channel Power Ratio,occupied Bandwidth, Emission
Bandwidth, Carrier-to-Noise Ratio, Carrier
Frequency |
| RTSA |
Channel Power, Adjacent
Channel Power Ratio,occupied Bandwidth, Emission
Bandwidth, Carrier-to-Noise Ratio, Carrier
Frequency |
| Time |
IQ vs. Time, Power vs.
Time, Frequency vs. Time, CCDF, Crest Factor
Pulse Measurements: Pulse Width, Pulse Peak
Power, On/Off Ratio, Pulse Ripple, Pulse Repetition
Interval, Duty Cycle, Pulse-Pulse Phase, Channel
Power, OBW, EBW, Frequency Deviation (Min
pulse length, 20 samples; Max pulse length,
360,000 samples) |
| Analog Demod |
IQ vs. Time, AM Depth,
FM Deviation, PM Deviation, Pulse Spectrum |
Views by Mode
| Mode |
Views |
| SA |
Spectrum |
| SA/Spectrogram |
Spectrum, Spectrogram |
| RTSA |
Spectrum, Spectrogram |
| Time |
Overview: Power vs.
Time, Spectrogram
Sub-view: Spectrum
Main view: Measurement Result |
| Analog Demod |
Overview: Power vs.
Time, Spectrogram
Sub-view: Spectrum
Main view: Measurement Result |

Screen layout, to identify analysis view locations
as described in the above chart
MEASUREMENT SPEED
Screen Update Rate - 2 MHZ Span, Auto
RBW: 19.4/s
Remote Measurement Rate and GPIB Transfer Rate
(2 MHZ span, auto RBW, spectrum data) - 1.87
waveforms/s, or 6,000 samples/s
RF Center Frequency Switching Time -
<10 ms for 10 MHZ frequency change
500 ms for 3 GHZ frequency change
TRACES, DISPLAYS, DETECTORS
Traces - Two traces, Spectrum Analyzer mode
Displays - Up to three time-correlated, user-selected
displays
Detector - RMS
Trace Types - Normal (RMS), Average, Max Hold,
Min Hold
Display Detection - Max, Min, Max/Min
MODULATION ANALYSIS
Analog
AM
Minimum Input Level - -40 dBfs, typical
PM
Minimum Input Level - -40 dBfs, typical
PM Scale, Max, Min - ±180°
FM
Minimum Input Level - -40 dBfs, typical
Range - ±Span/2 from center frequency
DEMODULATION ACCURACY
Analog
AM (-10 dBfs signal, input at CF, 10 to 60%
modulation depth) - ±2%
PM (-10 dBfs signal, input at CF) - ±3°
FM (-10 dBfs signal, input at CF) - ±1%
of span
RF Performance
FREQUENCY
Frequency Range -
RSA3308A/WCA280A: DC to 8 GHZ
RSA3303A/WCA230A: DC to 3 GHZ
Center Frequency Setting Resolution - 0.1 HZ
Frequency Marker Readout Accuracy, Baseband -
±(RE*3 × MF*4 + 0.001 ×
Span + 0.2) HZ
Frequency Marker Readout Accuracy, RF - ±(RE
× MF + 0.001 × Span + 2) HZ
Span Accuracy - ±1 bin
RBW Filter Bandwidth Accuracy - 0.1%
Reference Frequency -
Aging per day - 1 × 10-9 (after
30 days of operation).
Aging per year - 1 × 10-7 (after
30 days of operation).
Temperature Drift - 1 × 10-7 (10
to 40 °C).
Total Frequency Error - 2 × 10-7
(within one year of calibration).
Reference Output Level - >0 dBm.
External Reference Input - 10 MHZ, -10 dBm
to + 6 dBm.
Frequency Span -
Range, Spectrum Analyzer Mode -
50 HZ to 3 GHZ (Start Frequency =40 MHZ)
0 HZ to 40 MHZ (Stop Frequency <40 MHZ)
Range, Real-Time Spectrum Analyzer Mode -
100 HZ to 15 MHZ (RF)
0 HZ to 20 MHZ (Baseband)
Resolution Bandwidth Range - 2 KHZ to
2 MHZ, automatically selected or user-defined
Accuracy - Within 6.0% ±0.1%
Shape Characteristic - Gaussian with <5:1 shape
factor (3:60 dB)
Rectangular, Nyquist, Root Nyquist shapes may also
be selected.
*3 RE: Reference Frequency Error
*4 MF: Marker Frequency (HZ)
Minimum Settable RBW (Extended Resolution ON)
| Frequency |
RBW |
| Span >2 GHZ |
100 KHZ |
| 1 GHZ <Span
=2 GHZ |
50 KHZ |
| 500 MHZ <Span
=1 GHZ |
20 KHZ |
| 20 MHZ <Span
=500 MHZ |
10 KHZ |
| 500 KHZ <Span
=20 MHZ |
1 KHZ |
| 200 KHZ <Span
=500 KHZ |
500 HZ |
| 100 KHZ <Span
=200 KHZ |
200 HZ |
| 50 KHZ <Span
=100 KHZ |
100 HZ |
| 20 KHZ <Span
=50 KHZ |
50 HZ |
| 10 KHZ <Span
=20 KHZ |
20 HZ |
| 5 KHZ <Span
=10 KHZ |
10 HZ |
| 2 KHZ <Span
=5 KHZ |
5 HZ |
| 1 KHZ <Span
=2 KHZ |
2 HZ |
| 100 HZ <Span
=1 KHZ |
1 HZ |
Noise Bandwidth Range, RTSA Mode - 313.18 MHZ
to 400.87 KHZ
FFT Performance -
Number of samples per frame - 64 to 8192 (65,536 samples
per frame, extended resolution).
Window types - Rectangular, Parzen, Welch,
Sine-Lobe, Hanning, Sine-cubed, Sine-to-the-4th,
Hamming, Blackman, Rosenfield, Blackman-Harris 3A,
Blackman-Harris 3B, Blackman-Harris 4A, Blackman-Harris
4B, FlatTop.
STABILITY
Noise Sidebands, dBc/HZ
|
Offset |
At 1 GHZ CF |
At 2 GHZ CF |
At 6 GHZ CF |
|
|
Spec |
Typical |
Spec |
Typical |
Spec |
Typical |
|
1 KHZ |
-100 |
-107 |
-96 |
-99 |
-87 |
-90 |
|
10 KHZ |
-105 |
-112 |
-104 |
-107 |
-104 |
-107 |
|
20 KHZ |
-105 |
-112 |
-105 |
-108 |
-105 |
-108 |
|
30 KHZ |
-105 |
-112 |
-105 |
-108 |
-105 |
-108 |
|
100 KHZ |
-112 |
-115 |
-112 |
-115 |
-112 |
-115 |
|
1 MHZ |
-132 |
-135 |
-132 |
-135 |
-128 |
-131 |
|
5 MHZ |
-135 |
-140 |
-135 |
-138 |
-130 |
-133 |
|
7 MHZ |
-135 |
-140 |
-135 |
-138 |
-130 |
-133 |
Residual FM - 2 HZ, pk-pk, typical.
AMPLITUDE
Measurement Range - Displayed average noise
level to MAX safe input.
Input Attenuator Range -
RF/Baseband Input - 0 dB to 50 dB, 5 dB step.
IQ Input (Opt. 03) - 0 dB to 30 dB, 10 dB
step.
Input Attenuator Setting Uncertainty - ±0.5
dB (at 50 MHZ).
Maximum Safe Input Level -
Average Continuous (RF band, RF ATT =10 dB) -
+30 dB.
MAX DC Voltage -
±0.2 V, RF
±5 V, Baseband
±5 V, IQ input w/ Opt. 03
Log Display Range - 10 µdB/div to 10 dB/div
Linear Display Scale - 10 divisions
Linear Display Units - dBm, dBµV, V, Watts,
HZ for FM Demod, Degrees for PM Demod
Marker Readout Resolution, Log - 0.01 dB
Marker Readout Resolution, Linear - 0.001
µV
Frequency Response, 20 °C to 30 °C, RF ATT =10
dB
|
Frequency |
Spec |
Typical |
|
100 KHZ - 40 MHZ |
±0.5 dB |
±0.3 dB |
|
40 MHZ - 3.0 GHZ |
±1.2 dB |
±0.5 dB |
|
3.0 GHZ - 6.5 GHZ*5 |
±1.7 dB |
±1.0 dB |
|
5 GHZ - 8 GHZ*5 |
±1.7 dB |
± 1.0 dB |
Absolute Amplitude Accuracy at Calibration Point
(Baseband at 25 MHZ, -10 dBm signal, 0 dB ATT, 20
°C to 30 °C) - ±0.3 dB
Absolute Amplitude Accuracy at Calibration Point
(RF at 100 MHZ, -20 dBm signal, 0 dB ATT, 20 °C to
30 °C) - ±0.5 dB
Reference Level Setting Range -
1 dB step, RF, -50 dBm to +30 dBm
5 dB step, Baseband, -30 dBm to +20 dBm
5 dB step, IQ, -10 dBm to +20 dBm
Reference Level Accuracy (-10 dBm to -50 dBm at
100 MHZ, 10 dB ATT, 20 °C to 30 °C) - ±0.2 dB
Level Linearity in Display Range - ±0.2 dB,
spec; ±0.12 dB, typical
SPURIOUS RESPONSE
1 dB Compression (RF ATT = 0 dB, 2 GHZ CF) - +2
dBm
3rd Order Inter-modulation Distortion
(Ref Level = +5 dBm, RF ATT: adjusted for optimum,
total signal power = -7 dBm, CF = 2 GHZ) - -74
dBc
2nd Harmonic Distortion (-30 dBm tone
at input mixer, 10 MHZ to 1750 MHZ) - -56 dBc,
typical.
Displayed Average Noise Level, Specified, dBm/HZ
|
Frequency |
Spec |
|
10 MHZ |
-151 |
|
2 GHZ |
-150 |
|
3 GHZ |
-150 |
|
7 GHZ*5 |
-142 |
Displayed Average Noise Level, Typical, dBm/HZ
|
Frequency |
Typical |
|
1 KHZ -10 KHZ |
-144 |
|
10 KHZ -10 MHZ |
-151 |
|
10 MHZ -100 MHZ |
-151 |
|
100 MHZ -1 GHZ |
-150 |
|
1 GHZ - 2 GHZ |
--150 |
|
2 GHZ -3 GHZ |
-150 |
|
3 GHZ - 5 GHZ*5 |
-142 |
|
5 GHZ - 8 GHZ*5 |
-142 |
Residual Response
|
Frequency |
Spec |
|
1 to 40 MHZ (Span =20 MHZ, Ref Lvl =-30
dBm, RBW -100 KHZ) |
-93 dBm |
|
0.5 to 3.5 GHZ (Span =3 GHZ, Ref Lvl =-30
dBm, RBW =100 KHZ)*5 |
-90 dBm |
|
3.5 to 6.5 GHZ (Span =3 GHZ, Ref Lvl =-30
dBm, RBW =100 KHZ)*5 |
-85 dBm |
|
3.5 to 8 GHZ (Span =3 GHZ, Ref Lvl =-30
dBm, RBW =100 KHZ)*5 |
-85 dBm |
Spurious Response with Signal
|
Frequency |
Spec |
|
0 MHZ (Span =10 MHZ, Ref Lvl =0 dBm, RBW
-50 KHZ, Signal Frequency =25 MHZ, Signal
Level =-5 dBm) |
-73 dBc |
|
2 GHZ (Span =10 MHZ, Ref Lvl =0 dBm, RBW
-50 KHZ, Signal Frequency =2 GHZ, Signal
Level =-5 dBm) |
-73 dBc |
|
5 GHZ (Span =10 MHZ, Ref Lvl =0 dBm, RBW
-50 KHZ, Signal Frequency =5 GHZ, Signal
Level =-5 dBm)*5 |
-70 dBc |
|
7 GHZ (Span =10 MHZ, Ref Lvl =0 dBm, RBW
-50 KHZ, Signal Frequency =7 GHZ, Signal
Level =-5 dBm)*5 |
-70 dBc |
*5 Frequency >3 MHZ available on RSA3308A,
WCA280A only
INPUTS AND OUTPUTS
Front Panel
Input Connectors - N type, RF/Baseband; BNC
type, IQ, Opt. 03
Input Impedance - 50 O
VSWR, RF ATT >10 dB
|
Frequency |
Spec |
Typical |
|
300 KHZ -10 MHZ |
- |
<1.4:1 |
|
10 MHZ - 3 GHZ |
- |
<1.3:1 |
|
2.5 GHZ |
<1.4:1 |
- |
|
7.5 GHZ |
<1.8:1 |
- |
Preamp Power Connector - LEMO 6 pin connector
- Pin 1: NC; Pin 2: ID1; Pin 3: ID2; Pin 4: -12 V;
Pin 5: GND; Pin 6: +12 V.
External Preamp (Opt. 1A) - 100MHZ - 3GHZ,
20 dB gain, 6.5 dB Noise Figure at 2 GHZ (Typical)
Rear Panel
10 MHZ REF OUT - 50 O, BNC, >-3 dBm
10 MHZ REF IN - 50 O, BNC, -10 dBm to +6 dBm
EXT TRIG IN - Ext Trig, BNC, High: 1.6 to
5.0 V, Low: 0 to 0.5 V
GPIB Interface - IEEE 488.2
TRIGGER OUT - 50 O, BNC, High: >2.0 V,
Low: <0.4 V (output current 1 mA)
Side Panel
LAN Interface - Ethernet 10/100Base-T (Standard)
Serial Interface - USB 1.1, 2 ports
VGA Output - VGA compatible, 15 DSUB
General Characteristics
Temperature -
Operating: +10 °C to +40 °C.
Storage: -20 °C to +60 °C.
Warm-up Time - 20 min.
Altitude -
Operating: up to 3000 m (10,000 ft.).
Non-operating: up to 12,000 m (40,000 ft.).
Safety and EMI Compatibility -
UL 61010-1; CSA C22.2 No. 61010-1-04; IEC61010, Second
Edition (Self Declaration).
Low Voltage Directive 73/23/EEC, amended by 93/68/EEC;
EN61010-1: 2001 Safety Requirements for Electrical
Equipment for Measurement Control and Laboratory Use.
EC Council EMC Directive 89/336/EEC, amended by 93/68/EEC.
EN61326-1: 1997 Product Family Standard for Electrical
Equipment for Measurement, Control, and Laboratory
Use-EMC Requirements.
Electromagnetic Compatibility Framework:1992 AS/NZS
2064.1/2(Industrial, Scientific, and Medical Equipment).
Power Requirements - 100 VAC to 240 VAC, 47
HZ to 63 HZ.
Power Consumption - 400 VA max.
Data Storage - Internal HDD (40 GB), USB port,
FDD.
Weight, without options - 19 kg, 42 lbs.
Dimensions -
Without bumpers and feet: 215 mm (H) × 425 mm (D)
× 425 mm (W).
With bumpers and feet: 238 mm (H) × 470 mm (D) ×
445 mm (W).
Calibration Interval - 1 year.
Warranty - 1 year.
GPIB - SCPI-compatible. |